Rohs2.0 liquid chromatograph can provide fast analysis speed, high resolution, and keep the system low pressure to a great extent. Therefore, it retains the durability and working principle of conventional HPLC instruments and methods.
This design makes RRLC a general liquid analysis flow rate range, suitable for column size from 1 to 4.6-mm ID, column length from 10 to 300 mm, particle size from 1.5 to 10 μ M
Good degree of automation | With automatic dilution function, it can measure high concentration water sample |
Building block structure design | The style is novel and the structure is reasonable |
High performance variable wavelength UV Vis detector |
High detection sensitivity, extremely low noise and drift New optical design, concave holographic grating, high stability Wide wavelength range, multi wavelength time programming, full band pump stop scanning, the best detection wavelength can be selected The data can be directly output through R232 interface Long life, deuterium lamp more than 2000 hours |
High precision constant temperature column box |
Large capacity, can accommodate manual injector and any two chromatographic columns (15cm, 25cm, 30cm) Advanced low temperature control, suitable for low temperature separation of biological samples, etc. High precision of temperature control, temperature display in working state, over temperature alarm and automatic power off function |
Six way valve | Universal six way valve injection, simple operation, low noise, accurate quantitative |
P-101 high pressure pump |
The dual plunger reciprocating high-pressure pump has high-precision and steady flow performance; the pressure and corrosion-resistant imported gasket extends the service life; the patented pulsation buffer ensures the good effect of pulsation buffer; the software program control realizes the gradient elution of dual pumps Small pulsation, wide flow range, continuous adjustable, good flow repeatability, easy solvent replacement and so on Pressure detection and protection function, time and flow rate program control Easy maintenance: the pump body is easy to clean, repair and maintain; the plunger rod and sealing ring are easy to replace; the plunger rod cleaning function is provided to avoid the abrasion caused by salt buffer solution deposition on the plunger rod |
Chromatographic workstation |
All Chinese operation interface meets the needs of domestic users The convenient and intuitive counter control function can easily control the pump and detector With powerful data processing function, various quantitative algorithms can be realized Spectrum comparison function The curve correction function is easy to operate Automation: the automation of the whole process from spectrum collection to report printing; it can save series of spectrum to file for easy management Record the original data and related information of spectrogram, and follow GLP specification The report output format can be designed by ourselves The instrument information can be customized according to the requirements |
Index of high pressure infusion pump | |
Project | Main technical specifications |
Working pressure | 0~42MPa |
Flow range | 0.01-15.0mL/min |
Flow accuracy | RSD<0.1% |
Gradient range | Equal gradient, binary gradient |
Gradient accuracy | ±1% |
Column box index | |
Temperature range | Electric refrigeration 5 ℃~ 80 ℃ (room temperature < 25 ℃) |
Control accuracy | ±0.1℃ |
Two 15, 20, 25 and 30 cm long chromatographic columns can be installed in the column box at the same time | |
Index of UV-Vis detector | |
light source | Deuterium lamp |
Wavelength range | 190-700nm |
Band width | 5nm |
Wavelength indication error | ±0.1nm |
Wavelength accuracy | ≤0.2nm |
Wavelength scanning | Multi wavelength time programming (10 band) |
Linear range | >104 |
Noise | <1×10-5AU(Empty pool)、<1.5×10-5AU(With mobile phase) |
Drift | <3×10-4AU(Empty pool)、 <3×10-4AU(Empty pool) |
Pool volume | 5μL |
Minimum detection concentration | 5×10-9g/ml(Naphthalene) |
Product response instruction: RoHS&WEEE Directive, ROHS 2.0 directive, halogen-free directive, reach regulation, EN71 directive, cp65, hr.4040, ASTM-F963, GS ZEK 01.4-08, 2012 / 48 / EU, EU 94-62-ec (Directive), GB / t17592 and other domestic and foreign directives.
Common organic substances in products: Phthalates (PAEs), polycyclic aromatic hydrocarbons (PAHs), azo dyes (azo), formaldehyde, bisphenol A (BPA), dimethyl fumarate (dmfu), short chain chlorinated paraffins (SCCPs), dimethylformamide (dmfa), hexabromocyclododecane (HBCD), bromine (PBBs, PBDEs), chlorophenol, amino acids and other substances.
Medicine, Life Sciences | New drug development and research, biological function analysis, quality management |
Health and epidemic prevention | Clinical analysis, biochemical index analysis, metabolite analysis, etc |
Food | Determination of nutrients, functional food research, pesticide residues, additives analysis |
Chemical industry | Functional research, quality management |
Environmental analysis | The monitoring of water quality, atmospheric environment, marine environment, indoor air, and the detection of various pollutants |
Quality Supervision | Commodity inspection, quality inspection, import and export inspection and quarantine |
Teaching research | Experiment, scientific research and teaching |
Other areas | Such as water, power plants, judicial, public security and other departments of sample testing |